IBM Flash System 5000H

IBM FlashSystem® 5010 and IBM FlashSystem 5030 (formerly known as IBM Storwize V5010E and Storwize V5030E) are all-flash and hybrid flash solutions designed to provide enterprise-grade functionalities without compromising affordability or performance.
Built with the rich features of IBM Spectrum Virtualize™ and AI-powered predictive storage management and proactive support of Storage Insights™.
IBM FlashSystem 5000 helps make modern technologies such as artificial intelligence accessible to enterprises of all sizes.
Technician Specifications
| Specifications | IBM FlashSystem 5030 with IBM Spectrum Virtualize Software | IBM FlashSystem 5010 with IBM Spectrum Virtualize Software | 
| Models | IBM FlashSystem 5030 Models 2072-3H2 and 2072-3H4 | IBM FlashSystem 5010 Models 2072-2H2 and 2072-2H4 | 
| User interface | Web-based GUI | Web-based GUI | 
| Single or dual controller | Dual (Active/Active) | Dual (Active/Active) | 
| Connectivity (standard) | 10 Gb iSCSI (On the motherboard) | 1 Gb iSCSI (On the motherboard) | 
| Connectivity (optional) | 
				• 16 Gb/s Fibre Channel • 12 Gb/s SAS • 25 Gb/s iSCSI (iWARP or RoCE) • 10 Gb/s iSCSI  | 
			
				• 16 Gb/s Fibre Channel • 12 Gb/s SAS • 25 Gb/s iSCSI (iWARP or RoCE) • 10 Gb/s iSCSI  | 
		
| Cache per control enclosure /clustered system | 32GB or 64GB / 64GB or 128GB | 16 GB, 32 GB or 64 GB | 
| Drives supported | 
				Small form-factor 2.5-inch disk drives: • 900 GB, 1.2 TB, 1.8 TB and 2.4 TB @ 10k rpm • 2 TB @ 7.2k rpm SAS nearline Large form-factor 3.5-inch disk drives: • 900 GB, 1.2 TB, 1.8 TB and 2.4 TB @ 10k rpm, SAS (2.5-inch drive in a 3.5-inch drive carrier) • 4 TB, 6 TB, 8 TB, 10 TB, 12 TB, 14 TB @ 7.2k rpm 2.5-inch flash drives: • 800 GB, 1.92 TB, 3.84 TB, 7.68 TB, 15.36 TB and 30.72 TB  | 
			
				Small form-factor 2.5-inch disk drives: • 900 GB, 1.2 TB, 1.8 TB and 2.4 TB @ 10k rpm • 2 TB @ 7.2k rpm SAS nearline Large form-factor 3.5-inch disk drives: • 900 GB, 1.2 TB, 1.8 TB and 2.4 TB @ 10k rpm, SAS (2.5-inch drive in a 3.5-inch drive carrier) • 4 TB, 6 TB, 8 TB, 10 TB, 12 TB, 14 TB @ 7.2k rpm 2.5-inch flash drives: • 800 GB, 1.92 TB, 3.84 TB, 7.68 TB, 15.36 TB and 30.72 TB  | 
		
| Maximum drives supported | 
				Maximum of 504 drives per system and 1,008 drives in two-way clusters: • Small form-factor enclosure: 24 x 2.5-inch drives • Large form-factor enclosure: 12 x 3.5-inch drives • High-density expansion enclosure: 92 x 3.5-inch drives  | 
			
				Maximum of 392 drives per system: • Small form-factor enclosure: 24 x 2.5-inch drives • Large form-factor enclosure: 12 x 3.5-inch drives • High-density expansion enclosure: 92 x 3.5-inch drives  | 
		
| Maximum expansion enclosure capacity | 
				• Up to 20 standard expansion enclosures per controller • Up to 8 high-density expansion enclosures per controller  | 
			
				• Up to 10 standard expansion enclosures per controller • Up to 4 high-density expansion enclosures per controller  | 
		
| RAID levels | RAID levels 0,1,10 with distributed RAID 5 (CLI Only) and 6 | RAID levels 0,1,10 with distributed RAID 5 (CLI Only) and 6 | 
| Fans and power supplies | Fully redundant, hot-swappable | Fully redundant, hot-swappable | 
| Rack support | Standard 19-inch | Standard 19-inch | 
| Advanced functions included with each system | 
				• Virtualization of internal storage • Data reduction pools with thin provisioning, UNMAP, compression and deduplication • One-way data migration • Dual-system clustering  | 
			
				• Virtualization of internal storage • Data reduction pools with thin provisioning and UNMAP • One-way data migration  | 
		
| Size | 
				8.7 cm (3.4 in.) H x 48.3 cm (19.0 in.) W x 55.6 cm (21.9 in.) D Approximate weight: – Large form-factor control enclosure: • Empty: 18.0 kg (39.6 lb) • Fully configured: 28.3 kg (62.2 lb) – Large form-factor expansion enclosure: • Empty: 16.4 kg (36.1 lb) • Fully configured: 26.7 kg (58.8 lb) – Small form-factor control enclosure: • Empty: 19.0 kg (41.8 lb) • Fully configured: 27.3 kg (60.0 lb) – Small form-factor expansion enclosure: • Empty: 16.7 kg (36.7 lb) • Fully configured: 25.0 kg (55.2 lb)  | 
			
				8.7 cm (3.4 in.) H x 48.3 cm (19.0 in.) W x 55.6 cm (21.9 in.) D Approximate weight: – Large form-factor control enclosure: • Empty: 18.0 kg (39.6 lb) • Fully configured: 28.3 kg (62.2 lb) – Large form-factor expansion enclosure: • Empty: 16.4 kg (36.1 lb) • Fully configured: 26.7 kg (58.8 lb) – Small form-factor control enclosure: • Empty: 19.0 kg (41.8 lb) • Fully configured: 27.3 kg (60.0 lb) – Small form-factor expansion enclosure: • Empty: 16.7 kg (36.7 lb) • Fully configured: 25.0 kg (55.2 lb)  | 
		
| Operating environment | 
				Air temperature: – Operating: 10°C – 35°C (50°F – 95°F) at 30.5 m below to 3,000 m above sea level (100 ft below to 9,840 ft above) – Non-operating: -10°C – 50°C (14°F – 125°F) Relative humidity: – Operating: 20% – 85% – Non-operating: 8% – 80%  | 
			
				Air temperature: – Operating: 10°C – 35°C (50°F – 95°F) at 30.5 m below to 3,000 m above sea level (100 ft below to 9,840 ft above) – Non-operating: -10°C – 50°C (14°F – 125°F) Relative humidity: – Operating: 20% – 85% – Non-operating: 8% – 80%  | 
		
| Warranty | 
				Hardware: – Three-year warranty with 9 to 5 next-business-day response – Tier 1 customer-replaceable units and on-site repairs – Warranty service upgrades available Post-warranty support available Customer setup (initial installation and field upgrades)  | 
			
				Hardware: – Three-year warranty with 9 to 5 next-business-day response – Tier 1 customer-replaceable units and on-site repairs – Warranty service upgrades available Post-warranty support available Customer setup (initial installation and field upgrades)  | 
		
| Operating environment | For a list of currently supported servers, operating systems, host bus adapters, clustering applications, and SAN switches and directors, refer to the IBM System Storage Interoperation Center at: ibm.com/systems/support/storage/config/ssic | For a list of currently supported servers, operating systems, host bus adapters, clustering applications, and SAN switches and directors, refer to the IBM System Storage Interoperation Center at: ibm.com/systems/support/storage/config/ssic | 
<< Vissza
	IBM Quantum Safe megokdások
	
	 CSINFO Partner nap
	2025.11.20. csütörtök
	9,00-14,00 óráig
	
	Helyszín:
	Cactus Juice Gastro Pub
	1061 Budapest Jókai tér 5
	
	Parkolási lehetőség az épület előtt fizetős
		- Támogatás vége: 2025.10.02
 - 
		Nincs több: new hardware support,
server/client/guest OS updates, new security patches, or bug fixes - Technical support vége: 2027.04.02
 
További angol nyelvű információért kattints ide!
Frissítsen VMware 8.0-ra! További inromációért kattintson ide
IBM FlashSystem tárolók
IBM FlashSystem® Cyber Vault
	A hagyományos tárolókhoz képest
	
	- Nagyságrendi teljesítményfelvét csökkentés 
	- Nagységrendi válaszidő csökkenés 
	- Nagyságrendi átviteli sebesség növekedés
	- Beépített tikosítás
	- Nem módosítható adattárolás